FOR IN VITRO LABORATORY RESEARCH USE ONLY. NOT FOR HUMAN OR VETERINARY USE.

How we test

Every lot is tested by Freedom Diagnostics in Franklin, TN before it goes on sale. Here's what we test, what happens to a lot that fails, and how to check any report yourself.

Tested twice: the powder, then the vials

1

The powder

Purity, identity, and net peptide tested at Freedom Diagnostics before it's filled.

2

The finished vials

Purity, identity, net peptide, and endotoxin tested again, on vials from the finished lot.

Lots that fail are never listed.

What the finished-vial test checks

  1. 1

    Purity

    HPLC

    How much of the vial is the target peptide, and which impurities make up the rest. A lot must reach at least 99.0%.

  2. 2

    Identity

    LC-MS mass spectrometry

    The measured mass, checked against the mass of the sequence on the label.

  3. 3

    Net peptide

    Quantitative content

    Milligrams of peptide in the vial, with the counter-ion (acetate) from the maker's COA shown separately.

  4. 4

    Endotoxin

    Bacterial endotoxin test

    Bacterial endotoxin, in EU per mg.

The specification for each test is printed on the report next to the result.

A lot that fails is never listed

Lots that miss specification are rejected. Nothing goes on sale until its report is back and published.

Every report stays online

Each lot has its own page with the full report. It stays at the same address after the lot sells out, marked archived.

Check a report yourself

  • Scan the vial and see the report

    Every vial carries a serial. Enter it on the Verify page to open its lot's report.

  • Read the full report, not a summary

    The chromatogram, the mass spectrum, net peptide and endotoxin, with nothing cut out.

  • See where it was stored

    Each lot page shows its freezer temperature history, held at -20°C until it ships.

How we test · Proton Supply